STANDARD EQUIPMENT
Mounted on customer furnished single axle chassis.
A. TANK
- Tank construction of 10 gauge steel shell and full section surge plates, spill collar with 20" manhole and rollover
protection to meet HM-198A/HM-183 DOT hot asphalt requirements. Fiberglass 2" insulation covered with aluminum
jacketing. Ladder. Tank thermometer 50°-400° F. pencil type. Tank contents gauge in 100
gallon increments with dial visible from both cab and rear loading area.
B. CIRCULATING SYSTEM
- Circulating system includes auto suction/circulate/spray valve, removable strainer in pump suction line, and a 25
gallon flushing oil tank with line to asphalt pump. System includes all valves for loading, circulating in the tank,
spraying and unloading.
C. HEATING SYSTEM
- One 8” to 6” return U-type flue with LPG burner (1,000,000 BTU) with exhaust stack and includes 52 gallon LP frame
mounted tank.
D. POWER UNIT
- Crankshaft driven hydrostatic pump and motor for asphalt pump operation. Note chassis must have front crankshaft
opening. (Optional transmission PTO available). Includes computer control of asphalt application rate with digital
readout and radar ground speed system. Also includes remote cab control of all asphalt circulating control valves.
E. SPRAY BAR
- Full circulating 12’ spray bar consisting of 8’ center section, (2) 1’ folding non-removable sections, (2) 1’
removable extensions, with breakaway feature. Individual one foot electric/air on/off cab control of spray bar.
Electric/hydraulic spray bar lift, shift and wing fold cab control. Manual flip valve nozzle control every 4".
(Note chassis must have air supply.)
F. ASPHALT PUMP
- Asphalt pump is 400 GPM hydraulic motor driven.
G. MISCELLANEOUS
- Miscellaneous items include 25' rubber hand spray hose and gun, flanged fenders, tool box. Measuring stick,
aluminum in 50 gallon increments. Quick couplers on load and transfer lines. FMVSS-108 lights and wiring and steel
parts painted black.
OPTIONAL EQUIPMENT
A. TANK
- Sampling valve/gravity draw-off 3/4".
- Spill collar drain tube.
- One 2" dial type thermometer (50°-500° F.).
- One 4” dial type thermometer (50°-500° F.).
- Manhole strainer, 20".
B. HEATING SYSTEM
- Two 8" to 6" return U-type flues with LPG burners (1,000,000 BTU’s each) with exhaust stack and includes 52
gal LP frame mounted tank.
- One 8" to 6" return U-type flue with high pressure fuel oil burner with auto ignition, (995,000 BTU), exhaust
stack and includes 25 gal fuel oil tank (in lieu of standard LP burner with 52 gallon tank).
- Two 8" to 6" return U-type flues with high pressure fuel oil burners with auto ignition,
(995,000 BTU’s each), exhaust stacks and includes 25 gal fuel oil tank.
- Portable liquid propane burner includes 12' hose and valve.
- Outfire protection or LPG burners.
- Thermostatic outfire protection for LPG burners.
C. POWER UNIT
- PTO off transmission in lieu of crankshaft driven hydrostatic pump.
D. SPRAY BAR
- Additional extensions for electric-air one foot on/off control.
- Electric/air spray bar gang on/off in lieu of one foot controls.
- Additional extensions for gang on/off spray bar, each foot.
- One set of nozzles is standard with all spray bars, additional nozzles per foot (state size).
E. ASPHALT PUMP
- 200 G.P.M. positive displacement asphalt pump (in lieu of standard 400 G.P.M.).
F. MISCELLANEOUS
- Loading hose 12' x 3" flexible steel, male fitting one end, quick coupler other end.
- 4-way power right side mirror.
- Sealed lighting system in lieu of standard.
- Special paint in lieu of standard.
- Export processing.
|
|